Minds → Welding → What electrical installation and safety-disconnect requirements apply to resistance welding equipment under 29 CFR 1910.255? Answer in under 100 words.
US FederalOSHA

What electrical installation and safety-disconnect requirements apply to resistance welding equipment under 29 CFR 1910.255? Answer in under 100 words.

Under 29 CFR 1910.255, resistance welding equipment must be installed by a qualified electrician in conformance with Subpart S. A safety-type disconnecting switch or circuit breaker must be conveniently located at or near each machine to shut off power for servicing. External weld initiating control circuits must operate at not over 120 volts, and portable welding gun initiating switches must not exceed 24 volts.
Last verified: 2026-08-26 · Sources checked: 1/1 resolving · Next scheduled review: 2026-11-24

Details / How it works

All resistance welding equipment shall be installed by a qualified electrician in conformance with Subpart S of 29 CFR Part 1910. A safety-type disconnecting switch or circuit breaker must be provided to open each power circuit, conveniently located at or near the machine so that power can be shut off when the machine or its controls are to be serviced.

Numbers & thresholds

Requirement Threshold
External weld initiating control circuit voltage Not over 120 volts
Portable welding gun initiating switch voltage Not exceeding 24 volts
Capacitor discharge equipment (high voltage over 550 volts) Complete enclosures with interlocks and manual discharge switch required

Exceptions & edge cases

For capacitor discharge or stored energy resistance welding equipment involving high voltage (over 550 volts), the regulation requires complete enclosures with interlocks that interrupt power and short circuit capacitors when doors are open. Additionally, a manually operated switch or suitable positive device must be installed as an added safety measure to assure absolute discharge of all capacitors. Grounding of the secondary of welding transformers is required where technically practical; where not, center-tapped grounding reactors or safety disconnect switches are acceptable alternates.

Sources

  1. [1]U.S. National Archives, Electronic Code of Federal Regulations — 29 CFR 1910.255 — Resistance welding · as of 2026-08-26

Ask this MIND

This answer is static and source-locked. Ask Welding your version of this question.

Related questions

This is general information, not advice. Welding summarizes primary sources (OSHA, NIOSH) as of the dates shown. It is not tax/legal/immigration advice and doesn’t account for your situation. Consult a qualified professional before acting. About this MIND

This page is one mind’s knowledge, published.

MIND turns your documents into a queryable, citable knowledge graph.

Make your own MIND →
Content licensed CC BY 4.0 · Attribution: "Source: MIND (m-i-n-d.ai)" · License terms
© 2026 MIND · m-i-n-d.ai · All Minds · Welding · License · Privacy · Terms